N360C-CF SERIES 2/4/8/16 Zones Conventional Fire Alarm Control Panel
The N360C-CF Series fire alarm family consists of 2, 4, 8, and 16 zone conventional fire alarm control panels which uses conventional input devices. The panel accepts water flow devices, two-wire smoke detectors, four-wire smoke detectors, pull stations and other normally-open contact devices. Outputs include four Notification Appliance Circuits (NAC, SOUND1-4), three standard Form-A relays (alarm, trouble and supervisory) and an EIA-485 port to interface with remote annunciators and optional remote relay modules. The FACP is field programmable via the panel keypad. It also supervises all wiring, AC voltage and battery level.
2,4,8,16 Class B Initiating Device Circuits (IDCs). All zones accept conventional detectors and any normally open contact device, Four Class B Notification Appliance Circuits (NACs), One Form-A Alarm Relay, One Form-A Trouble Relay, One Form-A Supervisory Relay, 3.0 amps of system power, Max 20 conventional detectors in one zone. Auto/Manual mode setting enable walk test. Each Zone can be disabled. Sound output can be disabled. Manual active sound output enabled. Able to report short and broken circuit of detection zones. Designed with standby batteries and space provision for two sealed lead-acid batteries.
N360C-NW8200 SERIES 4/8/32 Zones Conventional Fire Alarm Control Panel
The N360C-NW8200 Series fire alarm family consists of 4, 8, and 32 zone conventional fire alarm control panels which uses conventional input devices. The panel accepts water flow devices, two-wire smoke detectors, pull stations and other normally-open contact devices. Outputs include two Notification Appliance Circuits (SOUND1-2), two standard Form-A relays (alarm and fault) and four Nomally Open Relay Output.
4, 8, and 32 Class B Initiating Device Circuits (IDCs). All zones accept conventional detectors and any normally open contact device, Sound output can be disabled. Manual active sound output enabled. Able to report short and broken circuit of detection zones. Designed with standby batteries and space provision for two sealed lead-acid batteries.
Conventional Photoelectric Smoke Detector
The device is photoelectric detector uses a state-of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panel.
Two LEDs on each detector provide local 360° visible alarm indication. They flash every 3~5 seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The detector can be reset only by a momentary power interruption.
Conventional Heat Detector
The device is a combination of rate-of-rise and fixed temperature heat detector using heat thermistor sensor. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panel.
Two LEDs on each detector provide local 360° visible alarm indication. They flash every 3~5 seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The detector can be reset only by a momentary power interruption.
Conventional Reflex Beam Smoke Detector
This is a long-interval reflection line infrared beam smoke detector which must be used together with a reflector. In case of smoke on the light path of the detector, the signal arriving at the receiver is reduced; when the light reduction rate reaches the preset threshold, the detector will produce the alarm signal; when the light beam is completely blocked, the detector will produce the fault signal to prevent the false alarm caused by non-fire blockage. Thanks to the built-in uniprocessor with excellent performance, the detector has a powerful analysis and judgment capability and can automatically complete the systematic debug, the compensation for external environmental parameter variation, and the judgment of fire alarm and fault, and also can give status indication through the indicator lamp and the signal output terminal.
The detector adopting a brand-new and reasonable structural design is sensitive in adjustment, correct in positioning, easy in installation, and simple and convenient in debugging method. The detector contains a group of alarm passive normally open contacts and a group of fault alarm normally closed contacts as well as 4-20mA standard signal output to be conveniently connected with the fire alarm system and DCS system of plants of fire fighting equipment.
Conventional Manual Call Point (Break Glass)
The conventional manual call point designed for conventional fire alarm system for reporting fire or emergency condition by pressing its break glass. The manual call point can be test by a test key without breaking the glass.
Conventional Manual Call Point
This conventional manual call point designed for conventional fire alarm system for reporting fire or emergency condition by its PUSH IN/PULL DOWN handle latches. One 470 ohm resistor is used on the PCB board between Zone+ and Zone- when the switch inside is closed. So this conventional manual call point is only used with conventional fire alarm control panel.
Conventional Manual Call Point (Weatherproof)
This conventional manual call point designed for conventional fire alarm system for reporting fire or emergency condition by its PUSH BUTTON latches. IP67 multiple waterproof, flame retardant, rugged, and durable material. Still applicable in bad environment. So this conventional manual call point is only used with conventional fire alarm control panel.
Conventional Alarm Bell
NERD360 Fire Alarm Bells are specially designed for fire alarm applications. The gongs are made of selected alloy steel to give the loud, resonant tones necessary in fire alarm systems. Two gong sizes are available to overcome different ambient noise level. The Fire Alarm Bells are of the underdome type with heavy duty mechanisms. Each bell is supplied with a mounting plate that fits any standard single-gang opening .
Emergency LED Lamp
ENRD360 EL-101 Emergency LED Lamp are built for durability and reliability. Best of all, it is quality tested before release for delivery. UL Listed and Heavy Duty Battery.
Self-Contained Emergency Exit Lamp
ENRD360 EL-101 Self-Contained Emergency Exit Lamp are built for durability and reliability. Best of all, it is quality tested before release for delivery. A high impact polycarbonate exit signs utilizes the most energy efficient LED technology. It includes an automatically rechargeable Ni-Cad battery option suitable for use in Damp Locations and built in surge protection for spikes in voltage caused by lightening and static build up on components. Lasts for 2 hours during power outages. This universal SINGLE or DOUBLE sided sign can be mounted on a ceiling, end wall, or back wall.
CEBU HEADQUARTER
Door 2, G.K. Chua Bldg,
Lopez Jaena St., Subangdaku,
Mandaue City, 6014 Cebu, Philippines
Tel: +63 32 3461223 / 3463979
DAVAO BRANCH
42 Jade St., Ecoland Phase 4
Matina, Davao City, 8021, Philippines
Tel: +63 082 2851570
MANILA BRANCH
Unit 206-207 Sierra Centre Bldg.,
#8 Dominggo Guevarra corner Sierra Madre St.,
Mandaluyong City, 1550, Manila, Philippines
Tel: +63 02 5764094 / 5310209
Hotline: +63 0932 8784845